What has plagued other timing systems and frustrated coaches and athletes is the problem of false switch changes being registered interfering with reliable timing of events. The false signals arise from two sources:
1. Switch Bounce - this problem is usually confined to tests involving a contact mat or some other type of mechanical switch. When the switch is depressed or released it might actually bounce producing additional switch change signals. The problem is not so evident in timing lights because most systems use transistors to act as the switch and have no mechanical parts.
2. False triggers - probably the most frustrating aspect of timing speed or agility tests are due to multiple switch changes being registered as parts of the body break the light beams as the athlete passes. For example imagine the scenario in the figure below.

A switch close will be registered when the runner passes through the light beam at 'A'. It will then open briefly at 'B' but then close again as the trailing arm breaks the beam. The result is a false switch change which most timing systems would interpret as the runner passing through the next light gate.
3. There have been attempts to overcome the problem of false triggers by using two light beams (about 30cm apart) per gate and requiring that both be broken at the same time to register a switch change. This is a hardware solution which works reasonably well in most situations because it assumes that the trunk of the athlete must be passing through the gate to break both beams. The problem is the expense, additional electronics, and power demands required to operate two light beams at every gate.
The Kinematic Measurement System overcomes both false triggers and switch bounce by using the processing power of the modern PC running Windows to intelligently analyze the switch signals and determine the most representative times for ON and OFF switch changes. Click here if you would like to see a demonstration of False Signal Processing in operation.
When false signal processing is enabled a minimum delay between consecutive ON signals can be set. For sprinting or agility tests this should be the absolute minimum time it would take the subject to move between any two consecutive gates. This is usually at least 1000ms. However, for tests involving contact mats and the contact time, jumping, or gait analysis tests a minimum delay of 100ms or less should be used. If the time between consecutive ON signals is less than the minimum then the times are adjusted in one of five ways: First ON, Second ON, Average ON, Longest ON, and Skip false switch change. The following figure details how these are determined:

Click here if you would like to see a demonstration of False Signal Processing in operation.
Return to Kinematic Measurement System Page